Canine Adenovims TypeⅠbelongs to the family Adenoviridae, the genus of mammalian adenovirus in the classification. It causes canine infectious hepatitis, (an acute septic infectious disease characterized by central necrosis of liver lobules, inclusion bodies in the nuclei of liver parenchymal cells and cortical cells, and prolonged hemorrhage.) This kit is used to detect canine adenovirus typeⅠantigen in the secretions from the eyes, nose and mouth of dogs, and to screen and assist in the diagnosis of canine adenovirus typeⅠ infection.
Test principle of the Canine Adenovims TypeⅠ Antigen Test Kit
This product uses rapid immunochromatography technology to detect canine adenovirus type I antigen in the secretions of the eyes, nose and mouth of dogs. If there was CAV I antigen in the sample, it would specifically bind to the recombinant protein labeled with colloidal gold to form a complex that moved along the chromatographic membrane and was captured by CAV I antibody coated on the membrane, showing a wine red line on the detection line (T). If the CAV I antigen is not present in the sample, no visible lines are formed at the T position. No matter the result is negative or positive, the C line should be colored, otherwise the result is invalid.
Components of the Infectious CAVⅠ-Ag Test Kit
Component
CY-CAVⅠ AG-01 (1 test)
CY-CAVⅠ AG-10 (10 tests)
CY-CAVⅠ AG-25 (25 tests)
Test device in foil bag (including test card,pipette &desiccant)
Sample Requirements of Canine Adenovims TypeⅠ Antigen Test Kit
Please refer to the instructions for use
This kit is only suitable for testing feline whole blood or serum samples (hemolysis and hyperlipidemia samples cannot be used).
Collect fresh samples and immediately put into the extraction buffer solution, which should be detected as soon as possible within 1 hour.
If samples were not timely detected, store within 24 hours at 2-8°C and store within 1 month at -20°C.
Product Performance Indifelineors
Sensitivity ≥ 95%.
Specificity ≥ 97.5%.
Precision: no more than one false negative and false positive results within the batch; the test lines & control line (cards) between three lots shall be uniform, and no more than one time of color difference between lots.
Stability: valid for 24 month if unopened & store 2-30°C.
Interpretation of Results
Negative: In the test window, only one fuchsia-colored line appear next to “C”. Positive: In the test window, two distinct colored lines appear next to “T” & “C” simultaneously. Invalid: No color line visible next to “C”.
NOTE: Invalid test results can be caused by a variety of reasons and should be re-tested.
“HCY, Health care for you” is our forever mission. We dedicate to offering safe & reliable products and medical services with our global creditable partners. HCY has already supplied to WHO, MAYO clinic, MGI, DDC, Yale University, Qorvo, Quanterix, Thomas Scientific, SD biosensor, Cardinal Health, Cleveland Clinic, Mars Petcare & LumiraDx, etc. in the past years.